The SpectralLED® Wafer Probe Illuminator is designed to be adapted to test head manipulators and handler instrumentation for wafer-level CCD and CMOS sensor test and calibration. Contact Gamma Scientific for configurations specific to your wafer tester requirements
Unprecedented Resolution and Accuracy for Camera and Image Sensor Calibration
- All solid-state solution delivers vastly reduced operating & maintenance costs
- > 99% uniformity over 110mm field of view
- Designed for rapid start-up, repeatable performance and maximum up-time
- Wavelength options from the UVA to the Near Infrared
- Quickly simulate any CIE illuminant or Macbeth™ / X- RITE™ Color Patch
- Built-in RMS spectral fitting for simulation of user imported spectra
- Constant current drivers & built-in optical feedback ensure accurate & flicker-free output in real-time
- ISO/IEC 17025 accredited by NVLAP (NVLAP lab code 200823-0) for calibration accuracy
Please contact us with your custom & OEM requirements
RS-7-4 Optical Specifications | |
---|---|
Spectral Range | 380 nm to 1,000 nm (Custom ranges available on request) |
Spectral Output | 32 discrete LED channels, 3 broadband LED Channels Visible resolution ~ 15 nm, NIR resolution ~ 50 nm (typical channel spacing) |
Spectral Bandwidth | Typical: Visible 20nm FWHM, NIR 50nm FWHM |
CCT Range | 1,900K to 40,000K |
Preset Spectra | CIE Illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, MacbethTM / X-RiteTM Color Patches |
Custom Preset Spectra | Configurable at time of order via API. Contact factory for details |
Accuracy Specifications | |
Illumination Stability | ≥ 99.99% after 50 ms for radiance or after 2,000 ms for color |
Illumination Accuracy | ± 1% Absolute, NIST traceable |
Spectral Accuracy | ± 1 nm centroid wavelength |
Color Accuracy | CIE 1931 x, y ± 0.003 |
Linearity | < 0.1 % RMS of full scale |
Temperature Stability | Within ± 1° C via active TEC |
Long-term Drift | Output ≤ 2% Spectral ≤ 1 nm (channel dependent) |
Electrical Specifications | |
Electrical Resolution | 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback |
Dynamic Range Adjustment | 4-5 decades typical (spectrum dependent) |
LED Control | Pure DC constant current with floating differential sensing |
General Specifications | |
Software | Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric and photometric units supported |
Interface Connectors | USB 2.0 type B and DB-9 |
Interface Protocol | Simple ASCII commands with optional binary block transfer |
Supported Operating Systems | USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) |
Input Voltage and Power | 100 to 240 VAC at 50-60Hz, 600W maximum |
Dimensions | Please contact factory for details |
Optional Upgrades | |
RS-7 Wavemon™ | Multi-channel photodiode system provides amplitude feedback & real-time wavelength measurements |
Specifications are subject to change without notice. |
RS-7 WavemonTM Multi-channel photodiode system with amplitude feedback and real-time wavelength measurement
The Wavelength Monitor System is a multi-channel photodiode system which provides amplitude feedback and real-time wavelength measurements. It consists of three photodiodes each with an independent transimpedance amplifier circuit. Proprietary optical filtering techniques allows for wavelength accuracy of +/-0.25nm and repeatability of +/-0.05nm. The Wavelength Monitor PCBA, photodiodes, and optical filter assembly is temperature stabilized using a Peltier cooler and thermistor in a PID feedback loop. This assembly is a discrete module which can be used with any RS-7 model.